#Vaillant condensate pipe Frozen solid boiler broken down

Posted on 03 March 2018 at 09:44 into Vaillant condensate pipes boiler broken down by HSP

Vaillant condensate has frozen

On Vaillant ecoTEC plus VU and VUW boilers fault code F29 may indicate a blocked condensate duct and fault code F68 can be a blocked condensate route. It’s possible that either of these fault codes could show up if the condensate pipe was blocked with debris or frozen. Fault code F77 can indicate a fault with a condensate pump if one is fitted.

During the low temperatures we are currently seeing nationwide, it is possible that your condensate pipe may have frozen, if the pipe exits to the outside of your property.

The condensate pipe is usually a white overflow pipe, similar to one you may find on a washing machine or sink waste pipe. It allows your boiler to dispose of condensation to an outside drain via this pipe. The pipe will usually be located on the external wall outside from where your boiler is.

1. Check that your condensate pipe has actually frozen

If your Vaillant boiler is showing one of the above fault codes (F28 or F29) on the boiler’s display screen or in some circumstances you can hear a bubbling and gurgling sound coming from your boiler this could mean your condensate pipe is frozen.

 

2. Locate the frozen blockage within the condensate pipe

Usually your condensate pipe will be frozen on the most exposed external point, this will normally be at the end of the pipe, just below the drain or around the bend where the insulation is at its thinnest.

3. Thaw your condensate pipe to remove the blockage

You can pour warm water along the condensate pipe to remove the ice blockage. Use a suitable container like a watering can and continue the process, until either the ice falls from the pipe or until the contents of the pipe are fully drained. Please do not use boiling water as this can damage the pipe.

4. Restart your boiler once ice blockage has been removed

You should always check your boiler manual for instructions on how to reset your boiler correctly before undertaking this operation, then you should restart your boiler.You can avoid having to repeat this process in future by insulating your condensate pipe. By insulating your condensate pipe you are reducing the risk of it freezing and blocking again in future. All good DIY stores should sell pipe insulation, this can easily be fitted with little effort.

Vaillant condensate pipe frozen